Chemical, slurry, mining applications. Surrounding air temperature, max: 60 °C: North American temperature code: T5: Emissions: IEC 61000-6-4: ESD immunity: 6 kV contact discharges, 8 kV air discharges This product was certified with the above certifications as of 2023-11-09. Please review the product label to check for the certifications your specific product carries. us@ifm. The module is seated when the latching mechanism (7) is locked into the module. Eurasion Economic Community. Phone 800-441-8246 email cs. High protection rating for the requirements of harsh industrial environments. This user manual provides detailed specifications, wiring diagrams, and programming examples for the module, which supports 8 single-ended or 4 differential inputs with 16-bit resolution. Lifecycle status: ACTIVE. Created Date: 2/27/1998 7:51:50 AMATEX. This technology helps extend the value of your investments across your process control and electrical distribution systems. 4. Flex 16 Point Digital Output Module. Overwrite. On the other end is the Removable Terminal Block (RTB) for the 1756 I/O module, as shown in the photo below. Standard Package. Provide a local safety connectivity to the Compact GuardLogix 5380. These solutions follow the. 7 x 2. Both the IFM-ready cables and the I/O module-ready cables have individually colored conductors for quick wire-to-terminal coordination. CompactLogix 16 Pt 24VDC D/O Module. • Analog interface modules (AIFMs) that provide the I/O terminal blocks for analog I/O modules. Includes terminals for landing power supply. Make certain that you only connect terminal base units to other intrinsi-Overview. 1492-IFM40F. The PLC-5 family used the 6200 series programing software originally and then later RSLogix 5 programming software. 5 mm (EN 50 022 - 35 x 7. Magnetic Flow Meters. Includes mechanical RTB keying, user-defined. Image by Dan Staifer. This product was certified with the above certifications as of 2023-11-09. Find a Distributor. The Bulletin 1756 ControlLogix® suite of chassis-based modules offer a wide range of options to meet your needs. Rockwell AutomationField-side diagnostics on select modules; Choice of direct-connect or rack-optimized communications; POINT Guard I/O™ modules for safety applications; Configurable modules. 2023 —- Learn how to set up the AS-Interface Ethernet/IP Gateway with an Allen-Bradley CompactLogix PLC, using a. Narrow Standard Interface Modules Modules Etroits d’interface Standard Schmale Standard-Schnittstellenmodule Moduli Ridotti per Interfaccia Standard. Fuses (5 x 20 mm) are not included. 1492 interface modules. The top 3 PLC manufacturers, according to industrial automation revenue, are Siemens with $18,281 million USD, Mitsubishi Electric with $13,346 million USD and Emerson with $12,202 million USD. Representative Rendering, Not The Actual Product. 1756-TD002. Please review the product label to check for the certifications your specific product carries. to avoid the risks of unauthorized and counterfeit products. Find all available product literature for this product in the Literature Library results . The module continuously scans adapters on the remote network. The result is a 100% digital path to your PLC from a field-mounted sensor. SKU: 88353850. Please review the product label to check for the certifications your. I/O blocks offer additional functions for signal preprocessing and expanded diagnostic options. 1100 Atwater Dr. to avoid the risks of unauthorized and counterfeit products. PUBLICATION NUMBER. Acquire input and output signals directly in the control cabinet or in your systems and machines. 888. Slide the module into the chassis until both top and bottom retaining clips are secured. Go to module definition and click on the change button. This type of information is requested continuously from the controller and is needed to control machines or processes. Views. This technical data sheet provides an overview of the product specifications, features, benefits, and accessories of the PanelView Plus 6 terminals. . , a 1N4004 diode reverse-wired across a DC load). 1. 1 kg (0. Fused Termination Module w/BF-Indication for SIL2 Safety Shutdown System Using 2 1756-IB32 Inputs , 1756-IB32: ControlLogix DC Input, 32 Pts. Name: View Type: select a view type compatibility view download view. 382. 4. Find Firmware & Downloads. DoRockwell Automation7Publication 1769-UM019A-EN-P - October 2008 7 Preface Introduction Read this preface to familiarize yourself with the rest of the manual. FLEX 5000 Analog I/O Modules Catalog Numbers 5094-IF8, 5094-IF8XT, 5094-IY8, 5094-IY8XT,. 1756-IB16S, 1756-OBV8SModule Publication Number Module Publication Number ArmorBlock I/O 8 Channel IO-Link Master Module Installation Instructions 1732E-IN001 ATTENTION: This equipment is intended for use in a Pollution Degree 2 industrial environment ATTENTION: Two sets of mounting holes are used to mount the module directly to a panel or machine. 1756-TD002. IECEx Scheme. Refer to the AIFM and ACABLE pinouts. no module label upper middle lower upper middle lower upper middle middle middle middle middle lower upper leve single ended current inputs shield 1746-n i16 1746-ni16v. 0. 1492-IFM20D120A-2 for input modules and Cat. Products sold before or after this date might carry different certifications. 2. 1732E ArmorBlock Dual-Port EtherNet/IP 4-point Isolated Thermocouple and RTD Input Modules User Manual 1732E EtherNet/IP ArmorBlock Supporting Sequence of Events User Manual 1732E ArmorBlock EtherNet/IP Dual Port 8-point Sequence of Events Input and Scheduled Output Modules User Manual ArmorBlock I/O 8-channel IO. 40-Point Isolated Digital IFM, 24/48V AC/DC LED Indicators, 4 Terminals per Input , Digital. Here is a list of the top 25 PLC manufacturers ranked. ifm efector, inc. Rockwell Control Logix. 40-Point Isolated Fusible Digital IFM, 5 x 20mm Fuse Clips, 4. Feed-Through 8 Channel Analog IFM, 3 Terminals per Input , Analog Interface Module. Each Allen-Bradley 1756 ControlLogix I/O module mounts in a ControlLogix chassis and requires either a removable terminal block (RTB) or a 1492 interface module (IFM) to connect all field-side wiring. Phone 800-441-8246 email cs. Steven. PUBLICATION NUMBER. In general, IO-Link offers three types of data that vary from sensor to sensor. Requires either a removable terminal block (RTB) or a Bulletin 1492 wiring interface module (IFM) to connect all field-side wiring. Please review the product label to check for the certifications your specific product carries. 40-Point Isolated Fusible Digital IFM, 5 x 20mm Fuse Clips, 24V AC/DC Blown Fuse Indicators, 4 Terminals per Input , , , Digital Interface Module. Put modern digital technology to work to simplify your operations and eliminate disparate control systems. Add to BoM. Quickly access technical specifications, installation instructions, and manuals for Allen-Bradley Bulletin 1762 MicroLogix Expansion I/O modules. Connects up to three chassis with 30 I/O modules to a single controller or communication adapter. 3. Remove and insert modules under power. 2 Scanner Backup Configuration CH2 TO/FROM OTHER PEER TOPEER CHANNELS SCANNER MODULE #1 SCANNER. no. No price available. The digital, bidirectional, point-to-point interface integrates with virtually any automated system. More Information: Rockwell Automation Publication 1794-IN050K-EN-P - October 2022 FLEX I/O Thermocouple/RTD Input Analog Module Installation Instructions ATTENTION: Read this document and the documents listed in the Additional Resources section about installation, configuration and operation of this equipment before you install, configure, operate or. Discontinued Date: 2021-12-31T00:00:00. All. Rockwell Compact Logix. 2 Rockwell Automation Publication 5094-UM002D-EN-P - November 2021 FLEX 5000 Analog I/O Modules User Manual Important User Information Read this document and the documents listed in the additional resources section about installation, configuration,. Products sold before or after this date might carry different certifications. The number of local I/O modules that are supported depends on t he controller. Installs in an SLC™ 500 chassis. Browse the database of questions and answers on a variety of products and technologies. Once you log in, Yahoo will verify you and send you back here where you'll be logged in!Publicación de Rockwell Automation 1769-SG001U-ES-P – Abril de 2018 3 Sistema CompactLogix Nodos de red Aplicación Studio 5000 Logix Designer®, versiones 31 y posteriores (1) 5069-L306ER, 5069-L306ERM, 5069-L306ERS2, 5069-L306ERMS2 16 1769-L30ER, 1769-L30ER-NSE, 1769-L30ERM, 1769-L30ERMK, 1769-L30ERMS 16. Products sold before or after this date might carry different certifications. 6 W, Current mode with 750 Ω loads = 9. 3 lb) I/O Adapters 87 x 68 x. Add to BoM. Find all available product literature for this product in the Literature Library results . Toutefois, en raison du courant de fuite généré par un fusible sauté dans le module 1492-IFM40F-FS24-4, la fonction de diagnostif "aucune charge" du 1756-OB16D ne signale pas un fusible sauté ou retiré comme une absence de charge. Spacing for single-wide modules 35mm (1. ControlLogix Input Module. Modules can be used to connect devices that do not have an ASI connection to the system. channel density modules, including a self-configuring discrete module, the modularity of POINT I/O minimizes system costs and size. 1746-OA16 output module, which uses the 1492-CABLE*CR cable. This product was certified with the above certifications as of 2023-11-13. The Modbus Driver module can connect directly to devices that support Ethernet communications or it can also connect to Modbus devices through a. They are cyclic, acyclic and events data. Customers are encouraged to migrate to our Compact 5000™ I/O modules used with the Logix control platform. Products sold before or after this date might carry different certifications. 0. 200 (filter)ArmorBlock 5000 I/O Blocks. The modules can operate in multiple input ranges based on the input type that is connected to the modules. Please review the product label to check for the certifications your specific product carries. Each 1769 Compact I/O module has a distance rating. The MPhil in Industrial Systems, Manufacture and Management (ISMM) is a one-year postgraduate masters course designed to equip outstanding graduates with the skills,. ifm efector, inc. With four channels for the connection of RFID antennas or digital I/Os. Quick-setup menu with intuitive operation. Our Bulletin 1756 ControlLogix® chassis-based modules provide a full range of digital, diagnostic digital, analog, motion control, specialty I/O, and compute modules to meet your application needs. This product was certified with the above certifications as of 2023-11-08. Our PartnerNetwork provides customers with an integrated team of engineering specialists and suppliers that are. The standard terminal modules are ideal for applications in which the I/O device commons are terminated in the field or remotely from the I/O module panel. . PUBLICATION NUMBER. Malvern, PA 19355. Standard terminal IFM modules provide one field-side wiring terminal per programmable controller input or output point, as well as enough terminals for the I/O module power connections. Representative Rendering, Not The Actual Product. The user can easily document the. Connection: 20 Pins Special Features: Standard Type: Digital Module with Fixed Terminal Block I/O Platform: Bulletin 1746 I/O Modules, Bulletin 1756 I/O Modules, Bulletin 1764. Malvern, PA 19355. Safety. Customers are encouraged to remove references to the affected product (s). Pott 1. A SIL 2 system is formed by one or more controllers, I/O modules, their power sources, communications networks, and workstations. 1756-TD002. Each point can be configured as a DC input or output; Available with DeviceLogix™ technology; 1734 POINT I/O Analog Modules. 884. Design and develop your industrial control system easier with a variety of configuration tools that include sample code, CAD drawings, and system architectures that help you determine what size system you might need to build. Lifecycle status: ACTIVE. 40-Point Feed-Through Digital IFM, Standard , , , Digital Interface Module. Includes optical coupling and filter circuitry which provides signal noise reduction. . Product Details. 7 s max, reference to the coordinated system time: Power dissipation, max: 4. 2 Rockwell Automation Publication 1756-UM010D-EN-P - September 2021 ControlLogix Configurable Flowmeter Module User Manual Important User Information Read this document and the documents listed in the additional resources section about installation, configuration, andUse your product. . Products sold before or after this date might carry different certifications. 1771-N High Resolution Isolated Analog I/O Modules - New conversion options in standard and combination 8. 4 as defined in IEC 61508, IEC 61511, IEC 62061, and ISO 13849-1. IECEx Scheme. Provides thermocouple and RTD modules. Color display for indicating the status of all AS-i slaves. 7. Knowledgebase. A SIL 2 system is formed by one or more controllers, I/O modules, their power sources, communications networks, and workstations. I/O MODULE DATA. Add to Repair Quote. ControlLogix 16 Pt 12/24V DC D/I Module. 4. 40-Point Feed-Through Digital IFM, Standard , , , Digital Interface Module. The 1756-IB16I has an operating voltage range of 10…30 Volts DC and a nominal input voltage of 24. Gain Operational Efficiency with a Wide Range of I/O Solutions. 07. Contact a Distributor Find A Sales Office. I/O Wiring and Conversion Systems. Updated Artwork Throughout Added Modules 5069-L310ERMK, 5069-L310ERS2K, 5069-L310ERMS2K, 5069-L310ERMS3K Throughout. Safety. Important User Information Solid-state equipment has operational characteristics differing from those of electromechanical equipment. Local I/O Modules 26 Compact 5000 I/O Modules 26 1734 POINT I/O Modules 30 1769 Compact I/O Modules 33. Safety Guidelines for the Application, Installation and Maintenance of Solid State Controls (publication SGI-1. This product was certified with the above certifications as of 2023-11-09. These modules have 5 x 20 mm fuse clips on-board and are available with and without blown fuse indication. 378 in. Port 1: Operztiong mode time 10-Ljnk device Byte swapThese high performance I/O blocks offer extended digital I/O capabilities such as input timestamp, Sequence of Events (SOE) and scheduled output that help improve machine precision and performance. Contact a Distributor Find A Sales Office. I/O Module, ControlLogix, Individually Isolated RTD, And Thermocouple, Inputs, 8 Channel. 12. I have the 2017 AutoCAD electrical, but this series does not exist in the PLC database. •Do not place this module in the same I/O group with a discrete high-density I/O module when using 2-slot addressing. No. ControlLogix 8 Point A/I Module. Drill and tap the mounting holes for the recommended M4 or #8 screw. 40-Point Isolated Digital IFM, 120V AC LED Indicators, 4 Terminals per Output , , , Digital Interface Module. Rockwell new Compact Logix I/O. . Product Overview - FLC - Field Logic Controller (ARGEE programmable) - Download (1825 KB) . Register this Product. You can add I/O, networks, drives, on-machine. PLC interfaces and pre-assembled cables - front adapters Interface modules Interface units Customised wiring solutions Easy system integration. 2 ++. Identification du module. comWe do not use a CP 343-2 but utilize an IFM AC 1411 gateway connected to the CPU via profibus cable. The Allen-Bradley®. It complements all Rockwell Automation® controller platforms for a distributed I/O solution. 2. Applying and Wiring the 1492-IFM20D24A-2 IFM module with a 1756-OB16E output card. 2 Rockwell Automation Publication 5094-UM002D-EN-P - November 2021 FLEX 5000 Analog I/O Modules User Manual Important User Information Read this document and the documents listed in the additional resources section about installation, configuration,. FLEX 5000 I/O systems are used as remote I/O modules with Logix 5000 controllers such as ControlLogix® 5580, CompactLogix™ 5380, and CompactLogix 5480. Safety monitors. to avoid the risks of unauthorized and counterfeit products. ifm efector, inc. This product was certified with the above certifications as of 2023-11-20. CE. The 5094-IY8 and 5094-IY8XT analog 8-channel universal input modules offer single-ended differential, non-isolated input channels as well as Thermocouple and RTD input channels that can operates in a wide range of applications. Product Details. Designed for use in harsh environments, our ArmorBlock 5000™ I/O offers the scalability that will help reduce total installation time and cost and unplanned downtime. This video explains how to open . title: 46006-325Rockwell Automation 1492-CABLE010Y Pre-wired cable for Isolated 1756 16-pt I/O Modules, 40 conductors, #22 AWG, w/1756-TBCH connector & IFM 40-pin connector, length 1. Technical Data. 1756-TD002. The number of field-side wiring terminals varies with the type of module from one to three terminals per I/O point. Cable connector pin type. . 3 W, Current mode with 500 Ω loads = 7. Hole spacing tolerance: ±0. PUBLICATION NUMBER. Rockwell Automation 16 Individually Fused Points Digital IFM, 4-Group Isolated, 5 x 20mm Fuse Clips, 24V AC/DC Low Leakage Blown Fuse Indicators, 4 Terminals per Input , 1756-IB16D: ControlLogix DC Diagnostic Input Module, 10-30V , Digital Interface Module40-Point Feed-Through Digital IFM, Standard , Digital Interface Module. 1794-TB3S 1794-TB3SK Spring clamp A spring clamp version of the 1794-TB3 – provides faster, simpler wire installation. 378 in. Remove the module from the chassis and replace the blown fuse with a 10A, 250V rectifier fuse (1/4 x 1-1/4 inch), Littelfuse part number 322010. Cable connector pin type. Lifecycle status: [email protected]. Product Details. China CCC. to avoid the risks of unauthorized and counterfeit products. ifm efector, inc. The Compact I/O™ 8 Channel Universal Analog Inputs Module provides 8 channels of voltage, current, and thermocouple, or 4 channels RTD/resistance in a single module. Find Product Drawings. individually isolated: Scheduled outputs: Synchronization within 16. Technical Data. Safety. The Analog input module is an intelligent block transfer module that interfaces analog input signals with any Allen-Bradley programmable controllers that have block transfer capability. The number of field-side wiring terminals varies with the type of module from one to three terminals per I/O point. 5 mm (EN 50 022 - 35 x 7. 2. 1794-TB32 Cage clamp 32 I/O; 8 common terminals; 8 +V terminals Up to 31. Gain Operational Efficiency with a Wide Range of I/O Solutions. Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 3. Products sold before or after this date might carry different certifications. This product was certified with the above certifications as of 2023-10-19. During installation, two penetrating mandrels pierce the insulation of the flat wire, allowing for a quick and easy connection with minimal assembly effort. module you are using and click on Submit. For a list of publications with information on Allen–Bradley programmable controller products, consult our publication index SD499. For Field-Side Wiring Diagrams, refer to the Wiring System web site information on page 200. Get Support. ATEX. These products are best-suited for packaging, material handling, and automotive applications. guelmi 7-28-2017 07 1 1 b sen 11 rtn ch0 sen 11 rtn ch1 exc 0 sen 12 exc 1 sen 12 sen 11 v2+ out com exc 2 v1+ out i 1 out comFeed-through. Use the safety module in a ControlLogix® chassis to provide safety I/O on a safety-control network that meets the requirements up to and including SIL 3, and PLe, cat. Rockwell Micro Logix 1400. 2 Rockwell Automation Publication 1756-UM010D-EN-P - September 2021 ControlLogix Configurable Flowmeter Module User Manual Important User Information Read this document and the documents listed in the additional resources section about installation, configuration, and 6 ArmorPoint 24V dc Output Modules, Series A Install the ArmorPoint Digital Output Module To install the ArmorPoint digital output module, proceed as follows. 1769-OB16. The latch will momentarily open and lock into place. 1756-IB16S, 1756-OBV8S Module Publication Number Module Publication Number ArmorBlock I/O 8 Channel IO-Link Master Module Installation Instructions 1732E-IN001 ATTENTION: This equipment is intended for use in a Pollution Degree 2 industrial environment ATTENTION: Two sets of mounting holes are used to mount the module directly to a panel or machine. Find a Distributor. I am asking if anyone has controlled an IO link device like an IFM Master IO link module to connect sensors to. 2. Technical Data. 20-Pin Relay Master Digital IFM, 120V AC, 16 Relays with Fusing , Relay Interface Module. The conversion module is an 18 point removable terminal block which connects directly to the 5069 modules. Order ifm efector, inc. Find a Distributor. . Rockwell Automation Publication 1732-SG001J-EN-E - April 2023 5 Chapter 1 ArmorBlock I/O Family Overview The ArmorBlock® I/O family is a hardened I/O product for On-Machine™ use. Meets Most Panel Specifications The I/O module-ready cables utilize #18 AWG conductors for strength and rigidity on longer cable runs. Repeat steps 1 to 6 for any. Mix and match I/O modules. . Apple iOS Mobile App . View All Industrial Flame Monitoring (IFM) S5XBE Series; Flare Stack Monitoring System Watchdog III; Industrial Flame Monitoring Accessories; FlameTools PC Monitoring. 3-1 Chapter Objectives. Allen-Bradley® catalog item 1756-IR12 from Rockwell Automation® is a temperature input module. Note that each ring node supports two EtherNet/IP ports. <2 ms to 95% of final value with resistive loads. No. to avoid the risks of unauthorized and counterfeit products. No patent liability is assumed by Rockwell Automation, Inc. IECEx Scheme. 0 Downloads. Dimensions — Refer to page 167. 5) or 35 x 15 mm (EN 50 022 - 35 x 15). Product drawing tools to help you design & apply our products. 2. Published Date 03/05/2020. Next, open RSLogix 5000 or Studio 5000 Logix Designer, and then go to Tools-> EDS Hardware Installation Tool: Image by Dan Staifer. Analog Module with. Find Product Drawings. Please review the product label to check for the certifications your specific product carries. ifm module reference 1492-aifm16-f-3 i/o cat . Please review the product label to check for the certifications your specific product carries. IECEx Scheme. This product was certified with the above certifications as of 2023-11-15. 5. with the I/O module, do not exceed the voltage and current ratings of the IFM. 3 7390566 / 0 4 03 / 201 9 Frank Hinnah Bernd Schneider2 Rockwell Automation Publication 1732E-IN001B-EN-E - July 2020 ArmorBlock I/O 8 Channel IO-Link Master Module Installation Instructions ATTENTION: Read this document and the documents listed in the Additional Resources section about installation, configuration and operation of this equipment before you install, configure, operate or. Rockwell Automation Publication 1756-IN083B-EN-P - August 2021 3 ControlLogix High-speed Counter Module Installation Instructions ATTENTION: This equipment is intended for use in a Pollution Degree 2 industrial environment, in overvoltage Category II applications (as defined in IEC 60664-1), at altitudes up to 2000 m (6562 ft) without derating. Bulletin number. Voltage mode = 6. User-friendly and simple configuration, set-up and diagnosis. Our Bulletin 1492 I/O Wiring Systems include interface modules and cables that connect through pre-wired cables to digital and analog I/O. , 10-31V ,Digital - Input / Output Mode , Digital Module for SIL2 (Safety Integrity Level 2). They are cyclic, acyclic and events data. Rack-type features in a rackless design lower costs and reduce replacement parts inventory. 6. Press firmly and evenly to seat the module in the terminal base unit. You can use any of the chassis-based modules in the local. I/O blocks from Balluff connect discrete and analog I/O sensors and actuators to the control level via a fieldbus or network. 40-Point Isolated Fusible Digital IFM, 5 x 20mm Fuse Clips, 24V AC/DC Blown Fuse Indicators, Extra Terminals for Outputs , Digital Interface ModuleAre you looking for a spec sheet of the 1492-AIFM8S-3 analog interface module? Download this pdf document to learn about its features, specifications, dimensions, and wiring. It describes theKnowledgebase. Add to BoM. 1. 1492 Wiring Systems Modules, Digital Module with Fixed Terminal Block, 40 Pins, LED Indicating, Isolated Extra Terminals for Outputs, 24V AC/DC, Four per I/O Connection Catalog #: 1492-IFM40DS24-4 FlagThe module is used in two modes, scanner and adapter mode. Find Product Drawings. Column 1: find the Catalog Number of the 1771 Module you are. This product was certified with the above certifications as of 2023-10-26. Modify Bulletin/Catalog Number: 1492-1FM40F 40-Point Feed-Througn Digital IFM, Standard , , Digital Interface Module Configuration Results & Drawings 1492-ift40f xModule Properties Report (ETHERNET-MODULE Iml) ETHERNET AL 1120 123 172 21 Zeess c_J . Modbus. 2) At the next screen displayed, click on the. Product type. Replace the module in the chassis and attach the field wiring arm. More Information: with output modules. Find Product Drawings. 40-Point Isolated Fusible Digital IFM, 5 x 20mm Fuse Clips, 24V AC/DC Blown Fuse Indicators, Extra Terminals for Outputs , Digital Interface Module One IFM versus multiple separate terminal blocks • Multiple interface module designs provide connection fl exibility – Feed-through – LED Indication – Fusing – Interposing relay and other options – Specialty 5370 L1 Controller Options I/O-Ready Flying Leads Cable Two Individual Cables: (1) Input IFM Connection and (1) Output IFM. Access technical specifications, installation instructions, and manuals for Allen-Bradley 5069 Compact 5000 I/O and chassis-based communication modules. Lifecycle status: ACTIVE. Please review the product label to check for the certifications your specific product carries. Please review the product label to check for the certifications your specific product carries. One per I/O connection. 4. 62 BTU/hr. To provide communication for ControlLogix 5570 or ControlLogix 5560 controllers, install the appropriate communication interface module into the local chassis. This product was certified with the above certifications as of 2023-11-09. 40-Point Isolated Fusible Digital IFM, 5 x 20mm Fuse Clips, 24V AC/DC Blown Fuse Indicators, Extra Terminals for Outputs , , , Digital Interface Module. Wiring Diagram 1756‐HSC 12…24V DC High Speed Counter / Encoder, 2 Channel 1 F 1492‐AIFMCE4 — —. Image by Dan Staifer. The other end is a female connector to connected directly. Rockwell Automation Digital IFM w/field Removable Terminal Block, (RTB) 20-Pin cable header, Feed-through Std. 36 x 3. 5m 'Y' Cable 1492-C025025UF for 16 Point Differential Current Wiring to. with the I/O module, do not exceed the voltage and current ratings of the IFM. Controllogix PLC Connect to IFM IO-Link Master via Ethernet using Rslogix 5000 V20AOI, Example Program and EDS download Link - Economic Community.